2016 Volume 5 Issue 1 Pages 46-52
In this study, four types of readily available artificial radon spa sources, sold as ceramic materials, were studied and dose estimations of the 222Rn emitted from them were made. When people use these sources in bathtub water for bathing, the equivalent dose received by the gonads has been estimated to be 0.40-0.63 nSv for each bathing time (30 min). When each source was put into tap water, the 222Rn concentrations each emitted ranged from 0.5 to 0.7 Bq L-1. If a person drinks 500 mL of water with a 222Rn concentration of 18 Bq L-1 every day, the personʼs maximum annual effective dose is estimated to be 12 nSv.